Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Arq. bras. oftalmol ; 86(4): 322-329, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447374

ABSTRACT

ABSTRACT Purpose: This study aimed to use computational models for simulating the movement of respiratory droplets when assessing the efficacy of standard slit-lamp shield versus a new shield designed for increased clinician comfort as well as adequate protection. Methods: Simulations were performed using the commercial software Star-CCM+. Respiratory droplets were assumed to be 100% water in volume fraction with particle diameter distribution represented by a geometric mean of 74.4 (±1.5 standard deviation) μm over a 4-min duration. The total mass of respiratory droplets expelled from patients' mouths and droplet accumulation on the manikin were measured under the following three conditions: with no slit-lamp shield, using the standard slit-lamp shield, and using our new proposed shield. Results: The total accumulated water droplet mass (kilogram) and percentage of expelled mass accumulated on the shield under the three aforementioned conditions were as follows: 5.84e-10 kg (28% of the total weight of particle emitted that settled on the manikin), 9.14e-13 kg (0.045%), and 3.19e-13 (0.015%), respectively. The standard shield could shield off 99.83% of the particles that would otherwise be deposited on the manikin, which is comparable to 99.95% for the proposed design. Conclusion: Slit-lamp shields are effective infection control tools against respiratory droplets. The proposed shield showed comparable effectiveness compared with conventional slit-lamp shields, but with potentially enhanced ergonomics for ophthalmologists during slit-lamp examinations.


RESUMO Introdução: Os oftalmologistas têm alto risco de contrair a doença do Coronavírus-19 devido à proximidade com os pacientes durante os exames com lâmpada de fenda. Usamos um modelo de computação para avaliar a eficácia das proteções para lâmpadas de fenda e propusemos uma nova proteção ergonomicamente projetada. Métodos: As simulações foram realizadas no software comercial Star-CCM +. Os aerossóis de gotículas foram considerados 100% de água em fração de volume com distribuição de diâmetro de partícula representada por uma média geométrica de 74,4 ± 1,5 (desvio padrão) μm ao longo de uma duração de quatro minutos. A massa total de gotículas de água acumulada no manequim e a massa expelida pela boca do paciente foram medidas em três condições diferentes: 1) Sem protetor de lâmpada de fenda, 2) com protetor padrão, 3) Com o novo protetor proposto. Resultados: A massa total acumulada das gotas de água (kg) e a porcentagem da massa expelida acumulada no escudo para cada uma das respectivas condições foram; 1) 5,84e-10 kg (28% do peso total da partícula emitida que assentou no manequim), 2) 9,14e-13 kg (0,045%), 3,19e-13 (0,015%). O escudo padrão foi capaz de proteger 99,83% das partículas que, de outra forma, teriam se depositado no manequim, o que é semelhante a 99,95% para o projeto proposto. Conclusão: Protetores com lâmpada de fenda são ferramentas eficazes de controle de infecção contra gotículas respiratórias. O protetor proposto mostrou eficácia comparável em comparação com os protetores de lâmpada de fenda convencionais, mas potencialmente oferece uma melhor ergonomia para oftalmologistas durante o exame de lâmpada de fenda.

2.
J. Transcatheter Interv ; 31: eA20230009., 2023. ilus; tab
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1511103

ABSTRACT

Introdução: As extensões de cateter-guia fornecem maior suporte em intervenções coronárias percutâneas complexas. O ExpressmanTM é uma nova extensão de cateter-guia, e nosso objetivo foi avaliar o impacto de seu uso no sucesso do procedimento e nas complicações ocorridas em um centro de referência de alto volume. Métodos: Analisamos os dados de todos os procedimentos consecutivos em que foi usada uma extensão de cateter-guia ExpressmanTM. A decisão de usar uma extensão de cateter-guia ficou a critério do operador. O sucesso do dispositivo foi definido como o posicionamento bem-sucedido da extensão de cateter-guia dentro do vaso coronário, e o sucesso do procedimento foi definido como <20% de estenose residual e fluxo TIMI 3, sem perda significativa de ramos laterais. Eventos adversos cardíacos e cerebrovasculares maiores foram definidos como a combinação morte por todas as causas, infarto do miocárdio, revascularização do vaso-alvo e acidente vascular cerebral. Resultados: Foram incluídos 34 procedimentos entre abril de 2022 e janeiro de 2023. A maioria dos pacientes era do sexo masculino (59%), e a média de idade foi 66,5 anos. O uso da extensão de cateter-guia não foi planejado antes do procedimento em 17 procedimentos (50%). Os motivos mais comuns para o uso da extensão de cateter-guia foram angulação ou tortuosidade do vaso-alvo e posição desfavorável do óstio coronário. O sucesso do dispositivo foi obtido em 88% e o da revascularização, em 91%. Houve três oclusões de ramo lateral. Durante o acompanhamento clínico intra-hospitalar, não ocorreram sangramento e nem eventos adversos cardíacos e cerebrovasculares maiores. Conclusão: O sucesso do dispositivo e do procedimento foi alto, e a taxa de complicações foi baixa. O uso da extensão de cateter-guia como técnica de resgate em anatomias complexas permitiu o sucesso do procedimento na maioria dos pacientes que, de outro modo, não poderiam ser tratados.


Background: Guide catheter extensions provide increased support in complex percutaneous coronary interventions. The ExpressmanTM is a novel guide catheter extension and the objective was to assess the impact of its use on procedural success and complications in a high-volume reference center. Methods: We analyzed data from all consecutive procedures in which the ExpressmanTM guide catheter extension was used. The decision to use a guide catheter extension was at operator's discretion. Device success was defined as the successful positioning of the guide catheter extension in the coronary vessel and procedural success was defined as <20% residual stenosis and TIMI 3 flow, with no loss of significant side branches. Major adverse cardiac and cerebrovascular events were defined as the composite of all-cause death, myocardial infarction, target vessel revascularization and stroke. Results: From April 2022 to January 2023, 34 procedures were included. The majority of the patients were male (59%) and the mean age was 66.5 years. Guide catheter extension use was not planned pre-procedure in 17 procedures (50%). The most common reasons for guide catheter extension use were target vessel angulation or tortuosity and unfavorable coronary ostium position. Device success was obtained in 88% and revascularization success in 91%. There were three side branch occlusions. During in-hospital clinical follow-up, no major adverse cardiac and cerebrovascular events or major bleeding occurred. Conclusion: The device success and procedural success were high and the rate of complications was low. Guide catheter extension use as bailout technique in complex anatomies allowed procedural success in the vast majority of otherwise untreatable patients.

3.
Arq. bras. oftalmol ; 83(5): 434-436, Sept.-Oct. 2020. graf
Article in English | LILACS | ID: biblio-1131625

ABSTRACT

ABSTRACT In this report, we describe a new pupil expander device that was used to obtain adequate pupil dilation and centering in a patient with an iris coloboma. Specifically, we describe the case of a patient with an iris coloboma; a Malyugin ring was inserted to facilitate dilation during phacoemulsifi­cation surgery. One of the scrolls did not engage which resulted in an uneven distribution of forces and an eccentric pupil. A Canabrava Ring was then implanted that promoted effective pupillary dilation and remained stable and effective throughout the surgical procedure.


RESUMO Neste relato, descrevemos um novo dispositivo expansor pupilar que foi usado obter adequada dilatação e centralização da pupila em um paciente com coloboma de íris. Especificamente, descrevemos um caso de cirurgia de facoemulsificação em um paciente com coloboma de íris associado à pupila pequena e que, previamente, tentou-se sem sucesso o uso do expansor Malyugin Ring, que provocou uma dilatação pupilar descentrada. Entretanto, com o uso do expansor de íris Canabrava Ring, a pupila permaneceu dilatada e centrada durante toda a cirurgia, permitindo a realização de um procedimento seguro.


Subject(s)
Humans , Cataract , Coloboma , Phacoemulsification , Cataract/complications , Pupil , Coloboma/surgery , Coloboma/complications , Iris/surgery
4.
Rev. bras. enferm ; 71(supl.6): 2833-2836, 2018. graf
Article in English | LILACS, BDENF | ID: biblio-977674

ABSTRACT

ABSTRACT Objective: to describe the development of a device to prevent falling for seniors when using the toilet. Method: we sought in literature and in the hospital market for a device to prevent falling, without success. Geriatric nurses, in partnership with the hospital engineering team, elaborated a prototype and, after several analysis, looked for a partner for its production. Results: the device, named "Safe Embrace", installed and tested in an apartment of the Geriatric ward, was positively evaluated by the health team, patients and caregivers. Conclusion: for the benefit obtained and considering the safety and privacy during use, Safe Embrace was patented so that other institutions could use it.


RESUMEN Objetivo: describir la elaboración del dispositivo de prevención de caídas para ancianos durante el uso del baño. Método: se buscó en la literatura y mercado del área hospitalaria un dispositivo para prevenir caída, sin éxito. Las enfermeras de la geriatría, en asociación con el equipo de ingeniería del hospital, elaboraron un prototipo y, tras varios análisis, buscaron un socio para su producción. Resultados: el dispositivo, denominado "Abrazo Seguro", instalado en un apartamento de la geriatría para la prueba, fue evaluado positivamente por el equipo de salud, pacientes y cuidadores. Conclusión: por el beneficio obtenido, y considerando la seguridad y privacidad durante el uso, el Abrazo Seguro fue patentado para que otras instituciones lo disfruten.


RESUMO Objetivo: descrever a elaboração do dispositivo de prevenção de quedas para idosos durante o uso do sanitário. Método: buscou-se na literatura e mercado da área hospitalar um dispositivo para prevenir queda, sem sucesso. Enfermeiras da geriatria, em parceria com a equipe de engenharia do hospital, elaboraram um protótipo e, após várias análises, procuraram um parceiro para sua produção. Resultados: o dispositivo, nominado "Abraço Seguro", instalado em um apartamento da geriatria para teste, foi avaliado positivamente pela equipe de saúde, pacientes e cuidadores. Conclusão: pelo benefício obtido e considerando a segurança e privacidade durante o uso, o Abraço Seguro foi patenteado para que outras instituições desfrutassem dele.


Subject(s)
Humans , Aged , Aged, 80 and over , Bathroom Equipment/standards , Patient Safety/standards , Inventions , Accidental Falls/prevention & control , Frail Elderly
5.
Arq. bras. oftalmol ; 79(2): 82-84, Mar.-Apr. 2016. tab, graf
Article in English | LILACS | ID: lil-782795

ABSTRACT

ABSTRACT Purpose: Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the present study was to evaluate the association between keratoconus evolution grade and topography pattern and the type and design of fitted contact lens. Methods: We performed a retrospective analysis of contact lenses fitted in a total of 185 patients with keratoconus (325 eyes). Keratoconus was classified as either grade I, II, III, or IV based on keratometry and cone morphology (nipple, oval, globus, or indeterminate) results. Results: A total of 325 eyes were evaluated in the present study. Of the 62 eyes classified as grade I, 66.1% were fitted with monocurve contact lenses. Of the 162 eyes classified as grade I and II, 51%, 30%, and 19% were fitted with adapted monocurve rigid gas-permeable contact lenses (RGPCL), bicurve lenses, and others lens types, respectively. Bicurve lenses were fitted in 52.1% and 62.2% of eyes classified as grade III and IV, respectively. Of the eyes classified as grade III and IV, monocurve and bicurve RGPCL were fitted in 26% and 55%, respectively. In eyes with oval keratoconus, 45%, 35%, and 20% were fitted with monocurve lenses, bicurve lenses, and other lens types, respectively. In eyes with round cones (nipple morphology), 55%, 30%, and 15% were fitted with bicurve lenses, monocurve lenses, and other lens types, respectively. Conclusion: Monocurve RGPCL were most frequently fitted in patients with mild to moderate keratoconus and oval cones morphology, while bicurve lenses were more frequently fitted in patients with severe and advanced keratoconus. This was probably because bicurve lenses are more appropriate for round cones due to increased corneal asphericity.


RESUMO Objetivo: O ceratocone é uma ectasia corneana bilateral e assimétrica que leva a afinamento corneano inferior e protrusão da córnea, não existe consenso sobre qual é o melhor caminho para adaptar lentes de contato em pacientes com ceratocone, considerando seus diferentes padrões topográficos e graus de evolução. O objetivo desse estudo é associar o grau de evolução e padrão topográfico com o tipo/desenho da lente adaptada. Métodos: Análise retrospectiva das lentes de contato adaptadas em 185 pacientes com ceratocone (325 olhos) no Departamento de Lentes de Contato. O ceratocone foi classificado de acordo com a ceratometria em graus I, II, III e IV e de acordo com a morfologia em cone redondo, oval, globoso e indeterminado. Resultados: Foram avaliados 325 olhos. Em 66,1% dos olhos com grau I foi adaptada lente monocurva. Dos 162 olhos classificados como graus I e II foram adaptadas lentes monocurva em 51%, bicurva em 30% e outros em 19%. Em relação aos olhos grau III, em 52,1% foram adaptadas lentes bicurvas e o mesmo aconteceu em 62,2% dos olhos com grau IV. Apenas 26% dos olhos grau III ou IV receberam lentes monocurva, com necessidade de bicurvas em 55%. 45% dos cones ovais foram adaptados com lentes monocurva, 35% com bicurvas e 20% com outros tipos, enquanto 55% dos cones redondos foram adaptados com lentes bicurvas, apenas 30% com monocurvas e 15% com outros desenhos. Conclusão: Lentes de contato rígida gás-permeável (LCRGP) monocurvas são mais frequentemente utilizadas em ceratocones leves e moderados e em ovais, enquanto bicurvas são mais usadas para casos graves e avançados e em cones redondos.


Subject(s)
Humans , Adolescent , Adult , Young Adult , Prosthesis Fitting/instrumentation , Contact Lenses , Contact Lenses, Hydrophilic , Equipment Design , Keratoconus/classification , Visual Acuity/physiology , Retrospective Studies , Corneal Topography , Keratoconus/pathology , Keratoconus/rehabilitation
6.
Arq. bras. oftalmol ; 79(1): 15-18, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-771899

ABSTRACT

ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS) and visual analog scale (VAS) by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males) diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57). The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042) and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034) scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.


RESUMO Objetivo: Comparar as respostas de dor de pacientes com retinopatia diabética proliferativa (PDR) submetidos à panfotocoagulação retiniana (PRP) usando laser de padrão de varredura (PASCAL) ou fotocoagulação navegada a laser (NAVILAS). Métodos: Pacientes com diagnóstico de PDR foram aleatoriamente designados para submeter-se ao tratamento de fotocoagulação com PASCAL ou NAVILAS. A PRP foi realizada no modo "multi-shot" com diâmetro do laser de 200-400 µm e duração do pulso de 30 ms, utilizados para se obter uma mancha branca-acinzentada na retina. Os parâmetros foram idênticos em ambos os procedimentos. Após 30 minutos da PRP, os pacientes foram solicitados a descrever verbalmente a sua percepção da dor como quer "nenhuma," "leve," "moderada," "intensa" ou "dor muito intensa" por meio de uma escala de avaliação verbal (VRS) e também por meio de uma escala visual analógica (VAS), indicando uma pontuação de "0" a "10" representando a intensidade da dor de "nenhuma dor" a "dor intensa." Resultados: Um total de 60 olhos de 60 pacientes (20 mulheres e 40 homens) com diagnóstico de PDR foram tratados. A média de idade dos pacientes foi de 62,22 ± 9,19 anos e a média de duração da diabete foi 195.47 ± 94,54 meses. O número médio de pulsos de laser emitidos durante a PRP foi 389,47 ± 71,52 no grupo NAVILAS e 392,70 ± 54,33 no grupo PASCAL (p=0,57). A diferença nas respostas de dor entre os pacientes nos grupos NAVILAS e PASCAL foi significativa em relação às médias de VRS (1,10 ± 0,67 e 1,47 ± 0,69; p=0,042) e VAS (2,13 ± 1,17 e 2,97 ± 1,35; p=0,034). Conclusões: As respostas de dor em pacientes submetidos à PRP com pulsos de 30 ms de duração foram significativamente menores nos pacientes do grupo NAVILAS em relação ao grupo PASCAL.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Diabetic Retinopathy/surgery , Eye Pain/prevention & control , Laser Coagulation/methods , Pain Measurement , Laser Coagulation/instrumentation , Random Allocation , Reproducibility of Results , Severity of Illness Index , Statistics, Nonparametric , Time Factors , Treatment Outcome , Visual Analog Scale
7.
Arq. bras. oftalmol ; 78(1): 19-22, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741162

ABSTRACT

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cornea/surgery , Phacoemulsification/instrumentation , Cell Count , Equipment Design , Endothelium, Corneal/cytology , Intraoperative Period , Operative Time , Postoperative Period , Preoperative Care , Prospective Studies , Phacoemulsification/methods , Single-Blind Method , Treatment Outcome , Visual Acuity/physiology
8.
São Paulo; s.n; 2014. [107] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-748472

ABSTRACT

INTRODUÇÃO: Evidências relevantes acerca dos benefícios da hipotermia terapêutica provieram da utilização de técnicas de resfriamento sistêmico. Essas técnicas, no entanto, podem causar complicações graves que poderiam ser evitadas com métodos de hipotermia encefálica seletiva. O presente estudo objetiva: 1) verificar a viabilidade da hipotermia encefálica exclusiva através de um sistema de resfriamento nasofaríngeo concomitante ao de preservação da temperatura corpórea em suínos e 2) investigar os efeitos da hipotermia encefálica exclusiva nas variáveis fisiológicas sistêmicas e encefálicas. MÉTODOS: Dez suínos híbridos foram submetidos a resfriamento nasofaríngeo durante 60 minutos e subsequente reaquecimento espontâneo. Foram obtidos dados referentes a: pressão arterial média, débito cardíaco, temperatura encefálica, pressão parcial de oxigênio do tecido encefálico (PbtO2, do inglês, pressure of brain tissue O2), velocidade do fluxo sanguíneo nas artérias encefálicas, índice de resistência e índice de pulsatilidade. RESULTADOS: O resfriamento nasofaríngeo associou-se à um decréscimo gradual da temperatura encefálica, que foi mais marcante no hemisfério cerebral esquerdo (p < 0,01). Neste hemisfério, houve redução de 1,47 ± 0,86°C nos primeiros 5 minutos (p < 0,01), 2,45 ± 1,03°C aos 10 minutos e 4,45 ± 1,36°C após 1 hora (p < 0,01). A diferença entre as temperaturas cerebral sistêmica foi 4,57 ± 0,87°C (p < 0,01). As temperaturas centrais (retal, esofágica e da artéria pulmonar), assim como a hemodinâmica encefálica e sistêmica, mantiveram-se estáveis durante o procedimento. Houve diminuição significativa da PbtO2, concomitantemente ao decréscimo da temperatura encefálica. CONCLUSÕES: A indução de hipotermia encefálica exclusiva é possível através de resfriamento nasofaríngeo associado a medidas de preservação da temperatura sistêmica. O resfriamento encefálico exclusivo não influencia as funções hemodinâmicas sistêmicas e encefálicas...


INTRODUCTION: Relevant evidences for the use of therapeutic hypothermia derive from studies using whole body cooling methods. These methods can lead to serious complications. To avoid such complications, selective brain cooling methods were developed. The objective of this study was: 1) to verify the feasibility of exclusive brain hypothermia by means of nasopharyngeal cooling along with measures of systemic temperature preservation in an experimental swine model, and 2) to investigate the influence of the exclusive brain cooling on cerebral and systemic hemodynamics as well as on cerebral oxygenation. METHODS: Ten hybrid swine underwent nasopharyngeal cooling for 60 minutes, followed by spontaneous rewarming. A number of physiological variables were monitored: arterial blood pressure, cardiac output, temperature in the right and left cerebral hemispheres, pressure of brain tissue O2, cerebral blood flow velocities, resistance index, and pulsatility index. RESULTS: Nasopharyngeal cooling was associated with decrease in brain temperature, which was more significant in the left cerebral hemisphere (p < 0,01). There was a reduction of 1.47 ± 0.86°C in the first 5 minutes (p < 0.01), 2.45 ± 1.03°C within 10 min, and 4.45 ± 1.36°C after 1 hour (p < 0.01). The brain-core gradient was 4.57 ± 0.87°C (p < 0,001). Rectal, esophageal, and pulmonary artery temperatures, as well as brain and systemic hemodynamics, remained stable during the procedure. PbtO2 values significantly decreased following the brain cooling. CONCLUSION: Achievement of exclusive brain hypothermia is feasible by means of nasopharyngeal cooling associated with measures of systemic temperature preservation. Selective brain cooling does not influence both systemic and cerebral hemodynamics, except PbtO2, which decreased significantly...


Subject(s)
Animals , Male , Female , Animal Experimentation , Equipment Design , Hypothermia, Induced/methods , Monitoring, Physiologic , Nasal Cavity , Nasopharynx , Oxygen Level , Swine , Brain Injuries, Traumatic , Ultrasonography, Doppler, Transcranial
9.
J. bras. pneumol ; 39(5): 595-603, Sep-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-695172

ABSTRACT

OBJECTIVE: To evaluate the performance of manual resuscitators (MRs) used in Brazil in accordance with international standards. METHODS: Using a respiratory system simulator, four volunteer physiotherapists employed eight MRs (five produced in Brazil and three produced abroad), which were tested for inspiratory and expiratory resistance of the patient valve; functioning of the pressure-limiting valve; and tidal volume (VT) generated when the one-handed and two-handed techniques were used. The tests were performed and analyzed in accordance with the American Society for Testing and Materials (ASTM) F920-93 criteria. RESULTS: Expiratory resistance was greater than 6 cmH2O . L−1 . s−1 in only one MR. The pressure-limiting valve, a feature of five of the MRs, opened at low pressures (< 17 cmH2O), and the maximal pressure was 32.0-55.9 cmH2O. Mean VT varied greatly among the MRs tested. The mean VT values generated with the one-handed technique were lower than the 600 mL recommended by the ASTM. In the situations studied, mean VT was generally lower from the Brazilian-made MRs that had a pressure-limiting valve. CONCLUSIONS: The resistances imposed by the patient valve met the ASTM criteria in all but one of the MRs tested. The pressure-limiting valves of the Brazilian-made MRs usually opened at low pressures, providing lower VT values in the situations studied, especially when the one-handed technique was used, suggesting that both hands should be used and that the pressure-limiting valve should be closed whenever possible. .


OBJETIVO: Avaliar o desempenho de reanimadores manuais (RMs) utilizados no Brasil conforme critérios definidos por uma norma internacional. MÉTODOS: Utilizando um simulador do sistema respiratório, oito RMs manuais (cinco produzidos no Brasil e três importados) foram avaliados em relação a resistência inspiratória e expiratória da válvula para o paciente; funcionamento da válvula limitadora de pressão; e volume corrente (VT) gerado por quatro fisioterapeutas voluntários, utilizando uma ou duas mãos. Para a realização e análise dos testes, foram utilizados critérios sugeridos pela norma da American Society for Testing and Materials (ASTM) F920-93. RESULTADOS: A resistência expiratória foi superior a 6 cmH2O . L−1 . s−1 em apenas um dos RMs testados. A válvula limitadora de pressão, presente em cinco RMs, abriu em baixas pressões (< 17 cmH2O), e a pressão máxima variou de 32,0-55,9 cmH2O. Houve grande variação da média de VT obtido pelos diferentes RMs. Os valores médios de VT utilizando uma mão foram inferiores ao sugerido pela ASTM (600 mL). O VT médio, nas situações estudadas, foi geralmente menor nos RMs nacionais com válvula limitadora de pressão. CONCLUSÕES: As resistências impostas pela válvula do paciente estão de acordo com os critérios da ASTM, com exceção de um RM. As válvulas limitadoras de pressão dos RMs nacionais geralmente abrem em baixas pressões, determinando o fornecimento de um menor VT nas situações estudadas, principalmente com o uso de uma mão, o que sugere que a ventilação deva ser feita com as duas mãos e a válvula limitadora de pressão deva ser fechada sempre que possível. .


Subject(s)
Female , Humans , Male , Intensive Care Units , Resuscitation/instrumentation , Ventilators, Mechanical/statistics & numerical data , Brazil , Comparative Effectiveness Research/methods , Computer Simulation/standards , Observer Variation , Respiratory Mechanics/physiology , Tidal Volume , Ventilators, Mechanical/standards
10.
ImplantNews ; 8(2): 247-251, 2011. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-599205

ABSTRACT

Desde que o conceito de osseointegração foi introduzido na Odontologia, várias mudanças ocorreram no modelo e na texturização de superfície dos implantes dentários. O objetivo deste estudo foi avaliar biomecânica e histologicamente diferentes macrogeometrias no período inicial da osseointegração na porção proximal da tíbia de cães Beagle. Seis cães Beagle adultos foram utilizados, onde 24 implantes tratados com jateamento com micropartículas e ataque ácido foram inseridos na porção proximal da tíbia bilateralmente (dois implantes por tíbia), 12 implantes cilíndricos com roscas triangulares (grupo controle) e 12 implantes cônicos com roscas trapezoidais (grupo experimental). Após a eutanásia, as tíbias foram removidas e destinadas ao teste de torque de remoção e processamento histológico. A análise estatística foi realizada através de teste t com intervalo de confiança de 95%. Os resultados para o torque de remoção foram 70 ± 20 Ncm e 120 ± 20 Ncm (média ± 95% de intervalo de confiança). Diferença estatisticamente significante entre os grupos foi encontrada (p < 0,001). Histologicamente, ambos os grupos apresentaram adequada biocompatibilidade e osseocondução com neoformação óssea nas regiões cortical e medular da tíbia. Baseado nos resultados obtidos, a macrogeometria com o tratamento de superfície empregados promoveu a osseointegração nos períodos iniciais do reparo e a macrogeometria do grupo experimental melhorou o desempenho para o torque de remoção comparado ao grupo controle. Novos estudos são necessários para confirmar suas potenciais vantagens.


Since the concept of osseointegration was introduced in dentistry, several changes concerning surface texture and macrodesign of dental implants were implemented. The objective of this study was to evaluate the effect of different implant macrogeometries on the early biomechanical and histomorphologic response in a beagle dog proximal tibia model. Six adult beagle dogs were used, and the implants with a grit-blasted and acid-etched surface were bilaterally placed along the proximal tibia (2 per limb)- 12 conic shaped with trapezoidal threads (experimental) and 12 cylindrical implants with triangular threads (control). After animal sacrifice, the limbs were retrieved and mechanical test and histological processing were performed. Statistical evaluation was performed by a Student´s t-test at 95% level of confidence. Removal torque test mean values were 70 ± 20Ncm and 120 ± 20Ncm for control and experimental groups, respectively (p < 0.001). Histological observations showed that both implant groups were biocompatible and osseoconductive, presenting newly formed bone at regions of cortical and trabecular bone. Based on results obtained, both macrogeometries and surface treatment presented osseointegration at early implantation times, and the experimental group geometry improved torque to interface fracture relative to the control geometry. Additional studies are necessary to confirm its potential benefits.


Subject(s)
Animals , Dental Implants , Equipment Design
11.
Rev. bras. oftalmol ; 69(1): 27-32, Jan,-Feb. 2010. tab
Article in Portuguese | LILACS | ID: lil-549432

ABSTRACT

OBJETIVO: Avaliar a espessura da camada de fibras nervosas da retina em olhos amblíopes e comparar com olhos normais e certificar se há correlação com a redução da acuidade visual. Além disso, este estudo se propõe avaliar a eficácia e eficiência em uma série de casos do protótipo de um equipamento nacional de magnificação para leitura. MÉTODOS: Participaram deste estudo 30 pacientes na faixa etária entre 9 e 80 anos (17 do sexo masculino). Foi desenvolvido um aparelho portátil, patenteado pela Unifesp (PI#020050145260), com um sistema de captura de imagens acoplado a um monitor de 5,6 polegadas proporcionando um aumento de 15 x. Foram analisadas a eficácia da acuidade visual e a eficiência de leitura após a utilização do protótipo proposto. RESULTADOS: Seis pacientes (20 por cento) apresentaram AV 8M, 12 pacientes (40 por cento) apresentaram AV 6M, 7 pacientes (23,3 por cento) apresentaram 5 M, 5 pacientes (16,7 por cento) apresentaram 4M. A média de acuidade visual antes da utilização do SLP medida pela tabela LHNV-1 logMAR foi de 5,75M e após a utilização 100 por cento dos pacientes atingiram a eficácia de AV J1. CONCLUSÃO: O protótipo do SLP mostrou-se um recurso alternativo no processo de inclusão social das pessoas com baixa visão com diferentes níveis de resíduo visual. Também pode proporcionar incentivo psicológico, permitir conforto, mobilidade e independência àqueles que necessitam de uma leitura mais prolongada e maior distância de trabalho.


OBJECTIVE: To compare the thickness of the retinal nerve fiber layer (RNFL)and the macular thickness of the amblyopic eye with those of the non-amblyopic eye in patients with unilateral amblyopia using optical coherence tomography (OCT). METHODS: OCT was performed for13 patients with unilateral amblyopia who had no neurologic disease. Nine male andfour female patients, whose ages ranged from 23 to 63 years, were enrolled in the study. The RNFL thickness average analysis program was used to evaluate mean superior, inferior, temporal, and nasal thickness. The data for all clock quadrants (12 values averaged) were identified as the overall RNFL. The retinal thickness analysis program was used to evaluate macular scans. Data were compared using the Man n-Whitney U test. The mean age ( standard deviation) was 35,43years. RESULTS: There were 13 eyes with amblyopia; this group had visual acuity 0,1 logMAR or better in the best eye. OCT parameters including the RNFL thickness in all quadrants, overall RNFL thickness and macular thickness showed no significant differences between the two groups (p >0,5). CONCLUSION: Assessment of RNFL thickness and macular thickness with OCT revealed no difference between the two eyes of patients with unilateral amblyopia.


Subject(s)
Humans , Male , Female , Child , Adolescent , Young Adult , Middle Aged , Amblyopia/complications , Vision, Low/rehabilitation , Nerve Fibers/pathology , Macula Lutea/anatomy & histology , Optic Nerve/pathology , Retina/pathology , Tomography, Optical Coherence , Visual Acuity , Retinal Ganglion Cells/pathology
12.
Rev. bras. oftalmol ; 68(5): 259-263, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-536426

ABSTRACT

OBJETIVO: A proposta deste estudo é avaliar a eficácia e eficiência em uma série de casos do protótipo de um equipamento nacional de magnificação para leitura. MÉTODOS: Participaram deste estudo 30 pacientes na faixa etária entre 9 e 80 anos (17 do sexo masculino). Foi desenvolvido um aparelho portátil, patenteado pela UNIFESP (PI#020050145260), com um sistema de captura de imagens acoplado a um monitor de 5,6 polegadas proporcionando um aumento de 15 X. Foram analisadas a eficácia da acuidade visual e a eficiência de leitura após a utilização do protótipo proposto. RESULTADOS: Seis pacientes (20 por cento) apresentaram AV 8M, 12 pacientes (40 por cento) apresentaram AV 6M, 7 pacientes (23,3 por cento) apresentaram 5 M, 5 pacientes (16,7 por cento) apresentaram 4M. A média de acuidade visual antes da utilização do SLP medida pela tabela LHNV-1 logMAR foi de 5,75M e após a utilização 100 por cento dos pacientes atingiram a eficácia de AV J1. CONCLUSÃO: O protótipo do SLP mostrou-se um recurso alternativo no processo de inclusão social das pessoas com baixa visão com diferentes níveis de resíduo visual. Também pode proporcionar incentivo psicológico, permitir conforto, mobilidade e independência àqueles que necessitam de uma leitura mais prolongada e maior distância de trabalho.


PURPOSE: The proposal of this study is to test and to validate as the effectiveness and efficiency in a series of cases the prototype of a national equipment of magnification to reading. METHODS: A recently developed of equipment of magnification (patent pending Brazilian Institutte of Industrial Property # 020050145260) was tested in a group of 30 patients (age range 9 to 80 years, 17 males). A portable apparatus was developed with a system of capture of images coupled with a 5,6 inch monitor, providing an increase of 15 X. The effectiveness of the visual acuity and the reading efficiency were analyzed after the use of the proposed prototype. RESULTS: Six patients (20 percent) presented AV 8M, 12 patients (40 percent) presented AV 6,0M, 7 patients (23.3 percent) presented AV 5M, 5 patients (16.7 percent) presented 4M. The average of visual acuity before the utilization of SPR measured by LHNV-1 logMAR chart was 5,75M. After the use of LHNV-1 logMAR chart, 100 percent (one hundred percent) of the patients reached the efficacy of AV J1. CONCLUSION: The prototype of SPR is an alternative resource in the social inclusion process of low vision patients with different levels of visual residue. It demonstrates psychological incentive, allows comfort, mobility and independence to those who need a more extended lecture and more distance of work.


Subject(s)
Biomedical Engineering , Vision, Low/rehabilitation , Equipment Design , Quality of Life , Reading , Brazil
13.
Arq. bras. oftalmol ; 71(3): 385-388, maio-jun. 2008.
Article in Portuguese | LILACS | ID: lil-486116

ABSTRACT

OBJETIVO: Avaliação preliminar na Clínica Oftalmológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (USP) de equipamento inovador para baixa visão desenvolvido na USP que consiste em prancha de leitura acoplada a lente de aumento que mantém fixos o foco e a linha de leitura. MÉTODOS: Foram avaliados 9 pacientes com visão subnormal usando o supracitado equipamento prancha de leitura acoplada a lente para auxílio em visão subnormal desenvolvida na USP em comparação com uso de uma lupa teste manual de dioptria semelhante, considerando-se os seguintes parâmetros de avaliação: causa da doença, acuidade visual corrigida no melhor olho para longe, impressão pessoal do paciente comparando prancha de leitura e lupa teste, impressão dos autores observando o uso dos 2 auxílios acima citados. RESULTADOS: A preferência pelos recursos foi: prancha de leitura acoplada a lupa - 5 pacientes; lupa manual - 2 pacientes; sem preferência por nenhum dos recursos - 1 paciente; inadequados para avaliação dos recursos preferidos - 1 paciente. CONCLUSÃO: Neste estudo preliminar, a maioria dos pacientes avaliados preferiu o recurso prancha de leitura acoplada à lupa, o que mostra que este produto inovador facilita a leitura; o médico avaliador interpreta a opinião do paciente como um especialista e contribui para o aprimoramento do produto para que ele possa ser futuramente submetido a novas avaliações.


ABSTRACT PURPOSE: To perform a preliminary evaluation at the "Clínica Oftalmológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (USP)" of an innovative equipment for low-vision developed at USP containing a reading stand and a magnifier that maintains in a stable position the reading line and focus. METHODS: 9 low-vision patients were evaluated using the above mentioned reading stand and a magnifier developed at USP comparing it with a hand magnifier of similar power taking into account the following evaluation parameters: etiology of low-vision, best corrected visual acuity for distance, patient's opinion comparing both low-vision aid resources, authors' opinion observing the patient using both low-vision aids. RESULTS: The numerical preference for the low-vision aids was: 5 patients for the reading stand and a magnifier that maintains at a stable position the reading line and focus; 2 patients for the hand magnifier; 1 patient indifferent regarding any of the resources; 1 patient inadequate for the evaluation of the low-vision aids. CONCLUSION: This preliminary study shows the preference of the majority of the patients for the reading stand and a magnifier that maintains at a stable position the reading line and focus showing that this innovative product makes reading easier; the evaluator doctor translates the patient's opinion as an expert and contributes to the improvement of the product so that it can be evaluated again in the future.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Humans , Middle Aged , Lenses , Optometry/instrumentation , Reading , Sensory Aids/standards , Vision, Low/rehabilitation , Equipment Design/standards , Ergonomics/instrumentation , Vision, Low/physiopathology , Visual Acuity/physiology
14.
Rev. bras. oftalmol ; 67(2): 69-81, mar.-abr. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-484535

ABSTRACT

OBJETIVOS: Estudar as lentes progressivas, à luz da óptica fisiológica, para mostrar os achados obtidos no lensômetro e a sua aplicabilidade na prática diária. MÉTODOS: Depois de explicar a forma de examinar as lentes, foram indicadas as bases físicas que permitiram o estudo, sendo levados em conta as variações do sistema prismático das lentes convexas e côncavas, as diferenças na extensão da zona de progressão e a razão da sua posição diagonal. O estudo foi realizado com 13 pares de lentes de uma mesma empresa e cobrindo todos os desenhos de lentes que ela disponibilizava na época do estudo.Todas as lentes tinham 2 D para longe (uma lente côncava e outra convexa) e as suas adições eram de 2 D. RESULTADOS: As lentes progressivas convexas têm na sua correção para longe um prisma de base inferior que depois de apresentar um local sem prisma passa a exibir um prisma de base superior. As lentes côncavas têm prisma de base inferior crescente.Ambas sofrem um desvio vertical médio, na amostra, de 5,86º, nas lentes convexas, e 6,93º nas lentes côncavas. CONCLUSÃO: Os autores, baseados nos achados, mostram os fatores que devem ser levados em conta no exame das lentes progressivas para minimizar a insatisfação ao uso dessas lentes. Nos estudos das lentes progressivas é considerado como primeiro plano a progressão sobre o plano secundário dos valores dióptricos enquanto nesse trabalho é considerado principal o valor dióptrico e a progressão secundária.


PURPOSE: This is to study the progressive addition lens (PAL) under the physiological optics' view, to show the lensometer findings and its applicability to daily work. METHODS: At first, the aa., explains the ways to examine the PAL , and then indicates the physical basis applied to study the prismatic system of the concave and convex lens. It then examines the differences on progression zone extension and explains its diagonal position. Thirteen pairs of lenses from the same manufacturer were examined but every pair had different drawing.The whole (convex and concave lens) had 2 Spherical Dioptries (SD) to distance and an addition of 2 SD. RESULTS: The convex PAL have to distance correction Inferior Base prism that do lower in progression zone to the point of no prism, and then continues with an increasing Superior Base prism to reach the near correction.The concave PAL has an Inferior Base prism rising constantly to near correction. Both have a mean vertical deviation in the sample of 5,86º in the convex lenses and 6,93º in the concave lenses. CONCLUSION: The aa., based on these findings, shows the most important data to watch in the PAL to minimize the complaints concerning its usage. The studies about PAL highlight that the dioptric values are the background of the progressive zone, and the aa. concludes that the dioptric values are the principal factor and, the progressive zone secondary.

15.
Arq. bras. oftalmol ; 71(2): 197-206, mar.-abr. 2008. ilus
Article in Portuguese | LILACS | ID: lil-483027

ABSTRACT

OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100 por cento maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.


PURPOSE: To develop the instrumentation and software for wide-angle corneal topography using a Placido-based videokeratographer. The objective is to allow the measurement of a greater area of the cornea using a simple adaptation to the Placido mire. METHODS: Using the traditional Placido disc of a commercial corneal topographer, 9 LEDs (Light Emitting Diodes) were installed on the conic mire so that the voluntary patient could gaze in different directions. For each direction Placido images were acquired and processed to form, using a sophisticated computer graphics algorithm, a tridimensional map of the whole cornea. RESULTS: It was shown that up to 100 percent more area of the cornea may be mapped using the here described technique. We present results for a spherical surface calibration and also for a highly astigmatic cornea and analyze quantitatively the additional area that is recovered in terms of curvature and true elevation. CONCLUSIONS: We believe that this new technique opens opportunities for the improvement of other applications which might benefit from this additional information, such as: contact lens adaptation and design improvement, algorithms for customized refractive surgery, among others.


Subject(s)
Humans , Cornea/pathology , Corneal Topography/methods , Image Processing, Computer-Assisted/methods , Lighting/instrumentation , Software , Algorithms , Astigmatism/diagnosis , Computer Graphics , Image Processing, Computer-Assisted/instrumentation , Lighting/methods
16.
Arq. bras. oftalmol ; 71(2): 234-237, mar.-abr. 2008. ilus
Article in English | LILACS | ID: lil-483032

ABSTRACT

PURPOSE: To develop in an interdisciplinary approach between ophthalmology and design areas an ergonomic +22-diopter 50-mm aspheric hand magnifier for low vision. METHODS: An aluminum cylinder was cut, processed using a lathe and carved to produce a ring that accommodated a 50-mm aspheric lens, with an external depression not to slide from the holder's fingers. A cylindrical steel bar was cut, processed using a lathe and carved in order to form an externally turned ring to be screwed into the internal thread of the aluminum ring, to maintain the lens in a steady position. Both rings were submitted to electrostatic painting with a dull black electrostatic Epoxi ink, except the lower border of the external ring, to indicate the correct side of the magnifier to face the material to be read. RESULTS: A 22-diopter 50-mm diameter aspheric lens magnifier with a black ring to be hold at its external circular depression was obtained in order to safely search the adequate reading focus with an inferior aluminum colored ring to face the object to be read and allow a less distorted reading. This is the first Brazilian high-magnification great-diameter magnifier for low vision that permits basically the focusing on an entire word, not only syllables, in order to allow a faster and more comfortable reading. CONCLUSIONS: By an interdisciplinary approach a 22-diopter 50-mm aspheric lens magnifier was developed with image and ergonomic characteristics such as to permit comfortable and adequate reading performance in cases of low vision.


OBJETIVO: Desenvolver de modo interdisciplinar entre as áreas de oftalmologia e design uma lupa de mão ergonômica de +22 dioptrias de 50 mm de diâmetro asférica para baixa visão. MÉTODOS: Um cilindro de alumínio foi cortado, torneado e teve feita internamente uma rosca a fim de produzir um anel para acomodar uma lente asférica de 50 mm de diâmetro com uma depressão externa para não escorregar dos dedos do portador. Uma barra de aço cilíndrica foi cortada, torneada e teve uma rosca feita para formar um anel com fio de rosca externo para ser rosqueado na parte interna do anel de alumínio, para manter a lente em posição estável. Ambos anéis foram submetidos a pintura eletrostática preta fosca exceto a borda inferior do anel externo para sinalizar o lado correto da lupa a ficar voltado para o material a ser lido. RESULTADOS: Foi obtida uma lupa de 22 dioptrias de 50 mm de diâmetro com um anel preto para ser segurado pela sua depressão circular externa a fim de procurar com segurança o foco adequado de leitura e com um anel inferior aluminizado para apontar para o objeto de leitura e permitir uma leitura menos distorcida. Esta é a primeira lupa brasileira de grande diâmetro e grande aumento para baixa visão, asférica, permitindo a focalização de uma palavra inteira, não apenas sílabas, proporcionando leitura mais rápida e confortável. CONCLUSÃO: Foi desenvolvida de modo interdisciplinar uma lupa de +22 dioptrias, de 50 mm de diâmetro, asférica, com tal qualidade de imagem e características ergonômicas para permitir leitura de desempenho adequado e confortável em casos de baixa visão.


Subject(s)
Humans , Lenses , Vision, Low/rehabilitation , Aluminum , Brazil , Equipment Design , Ergonomics , Ophthalmology , Optics and Photonics , Optometry , Reading
SELECTION OF CITATIONS
SEARCH DETAIL